Asset synchronization lets SEMOSS nodes refresh local copies when engines, projects, or other shared assets change. The current abstraction is IClusterSynchronizer, with Redis and ZooKeeper implementations.
| Setting | Purpose |
|---|---|
SEMOSS_IS_CLUSTER |
Enables cloud/shared-asset behavior in the configured deployment |
SEMOSS_IS_CLUSTER_REDIS |
Selects Redis asset synchronization |
SEMOSS_IS_CLUSTER_ZK |
Selects ZooKeeper asset synchronization |
| Storage-provider settings | Select the central storage backend and connection details |
HOST_IP in the Compose examples |
Gives each application node a distinct advertised identity |
Configure one asset coordination backend. ClusterSynchronizerFactory chooses Redis first if both flags are enabled and logs a warning; relying on that precedence makes deployment intent unclear.
Use the exact settings in the Redis Compose example or ZooKeeper Compose example. A single node can use shared object storage without either synchronization backend.
| Component | Responsibility |
|---|---|
| ClusterUtil | Entry points used by core operations to synchronize assets |
| CentralCloudStorage | Transfer files to/from the configured storage backend |
| IClusterSynchronizer | Common coordination contract |
| RedisClusterSynchronizer | Redis-backed notifications and coordination |
| ZKClusterSynchronizer | ZooKeeper/Curator-backed notifications and coordination |
At a high level, a node updates its working copy, pushes the relevant assets, and publishes a change. Other nodes process the notification and refresh applicable loaded resources. The synchronizer carries coordination information; asset contents come from central storage.
The exact push/pull operation depends on the resource and mutation. Consult its ClusterUtil call and synchronizer implementation instead of assuming every filesystem write automatically publishes a change.
Redis also serves separate room/agent features:
RoomMessageStorecan use Redis as a hot projection and coordination layer while persisting conversation history inROOM.MESSAGES.- The cached projection is disposable. Each write sets a sliding expiry of
ROOM_MESSAGE_REDIS_TTL_HOURS(default1), and the projection is evicted when a room is deleted, a guardrail closes it, or the user's session ends (logout or timeout). A missing projection reloads fromROOM.MESSAGESon the next read. Lock and turn-lease keys keep their own TTLs. ClusterRoomTurnLockuses Redis for a renewable per-room agent lease whenAGENT_RUN_QUEUE_ENABLEDis enabled. The default follows Redis availability; an explicit opt-in still requires Redis.AGENT_RUN_ACTIVE_TTL_MScontrols that lease's lifetime, not an agent's execution budget.
ZooKeeper asset synchronization alone does not enable these Redis services. Neither backend turns the process-local agent event buffer into a durable event log. See agent runs.
Run one of the two-node examples and check both nodes' startup logs for the intended backend and unique identities. Perform a supported resource update, confirm its central-storage copy, and verify that the other node refreshes the corresponding resource. Separately test room turns and live polling if the deployment uses agents across nodes.
For complete infrastructure examples, see SEMOSS-deployment. For asset layout and transfer responsibilities, see central storage.