The product id you supplied looks like a device id. This is a different value. If you used the cloud assisted config flow, the product id should be in your log just before the log message with the false match above. Otherwise, you can find it in the tuya developer portal in the same API calls that give up the local key. |
You're right. Product_id is Device_id is Uuid is |
Some additional info: When "Operation switch" (id 106) is set to dehumidify, the mode switch (id 5) is active, but when "Operation switch" (id 106) is set to fan_only, the fan speed switch (id 103) is active You can't change the mode and the fan speed at the same time. Also Error P3 (id 19) is just a warning for the filter, device is working normally. All other errors will disable the unit. |
Hi, I have on id 19 the value 9 which are errors C1 AND P3.
|
Log message
Product ID
y098ayyxswrena7t
Product Name
Inventor Rise Pro 8L
DPS information
Information about how the device functions
Dehumidifier with Ionizer and Ultraviolet type C led.
Manual
Error codes
l C1: NTC1 is open cut or short cut
l C2: NTC 2 is open cut or short cut
l C3: NTC1 &NTC 2 are open cut or short cut
l C4: Sync motor failure
l 88: Temperature and humidity sensor failure
l P2: Water tank full
l P3: Pre-filter clean reminder