Describe The Bug:
Occasionally pico remotes will stop functioning. Upon closer inspection in the HK logs it looks to be logging a release action but no press action.
To Reproduce:
Steps to reproduce are inconsistent. Homebridge restarts seem to fix temporarily most times.
Expected behavior:
Any press and release of a pico remote should result in either a short, long or double press action
Logs:
[11/5/2024, 9:37:30 AM] [Lutron] Button /button/121 on Pico remote Office Pico got action Release
[11/5/2024, 9:37:45 AM] [Lutron] Button /button/121 on Pico remote Office Pico got action Release
[11/5/2024, 9:37:51 AM] [Lutron] Button /button/122 on Pico remote Office Pico got action Release
[11/5/2024, 9:38:01 AM] [Lutron] Button /button/122 on Pico remote Office Pico got action Release
[11/5/2024, 9:38:09 AM] [UniFi Protect] Front Door [G4 Doorbell Pro]: Unable to retrieve a snapshot: using the most recent cached snapshot instead.
[11/5/2024, 9:38:30 AM] [Lutron] Button /button/122 on Pico remote Office Pico got action Press
[11/5/2024, 9:38:30 AM] [Lutron] Button /button/122 on Pico remote Office Pico got action Release
[11/5/2024, 9:38:30 AM] [Lutron] button /button/122 got a short press
[11/5/2024, 9:38:34 AM] [Lutron] Button /button/121 on Pico remote Office Pico got action Press
[11/5/2024, 9:38:35 AM] [Lutron] Button /button/121 on Pico remote Office Pico got action Release
[11/5/2024, 9:38:35 AM] [Lutron] button /button/121 got a short press
The text was updated successfully, but these errors were encountered:
Describe The Bug:
Occasionally pico remotes will stop functioning. Upon closer inspection in the HK logs it looks to be logging a release action but no press action.
To Reproduce:
Steps to reproduce are inconsistent. Homebridge restarts seem to fix temporarily most times.
Expected behavior:
Any press and release of a pico remote should result in either a short, long or double press action
Logs:
The text was updated successfully, but these errors were encountered: