Skip to content
blasagnaPublic

About

Playing with tools inspired by Remy's therapies

Resources

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

remapy

Playing with tools inspired by Remy's therapies

NOTE: This is a work in progress

Remy + therapy + python = remapy

Much of this is implemented using Claude code and other coding LLMs. I build similar tools to sample sensors from embedded systems and process them in my day job.

Motivation

My son Remy has a rare genetic syndrome that causes global developmental delays, in both movement and cognitive function (more at rareremy.org). While we pursue therapeutic development and medical research, most of our day-to-day energy goes into physical and occupational therapy with him.

remapy is a place to build tools that motivate Remy in those therapies and that can track changes in his abilities before they're visible in his gross actions. If therapeutic development advances to a clinical trial, the same tools can help establish a baseline of his abilities before treatment and measure progress or change afterward.

Pose estimation on a session with Remy

References

Standard, clinically validated exercises and scoring systems this project draws on for motor-development metrics:

Not currently used:

  • PDMS-3 — Peabody Developmental Motor Scales, Third Edition. Gross-motor subtests (Body Control, Body Transport, Object Control) plus fine-motor and a supplemental physical-fitness subtest. Pearson · WPS · PAR
  • AIMS — Alberta Infant Motor Scale. 58 observational items across prone, supine, sitting, and standing positions, norm-referenced from birth to 18 months. Physiopedia · Score sheets (Elsevier)

TODO

  • increase IMU sampling rate to at least 50, ideally 100 Hz — 100 Hz over USB serial, 50 Hz over BLE, both measured at 100 % of nominal
  • measure streaming throughput compared to nominal sampling rates — --stats now reports a device-clock rate + max gap alongside host arrival rate; this is how the above was verified, and it caught the rate silently decaying with board uptime
  • baseline IMU signal stats at rest — see Sensors (accel RMS σ ≈ 0.0102 m/s², gyro ≈ 0.0021 rad/s at the shipped ODR 208)
  • implement metrics from standard exercises and scoring defined in GMFM-88 — four trials (sitting hold, sit↔prone transition, belly crawl, supported standing), offline, camera-only. The instruments score ordinally (GMFM items are 0–3), which is too coarse to show change: Remy can sit at a "2" for a year while genuinely improving. So the items are not reimplemented — each one defines a reproducible trial, and motor_metrics/ measures the continuous variable underneath it (hold duration and postural sway; transition smoothness via SPARC; crawl cadence and left–right reciprocity). Label trials with pixi run annotate, then pixi run metrics / notebooks/motor_metrics.ipynb
  • compute metrics in real time (GUI overlay) as well as offline — the tilt-robust, trigger-free subset: pixi run live (sway + trunk lean) / pixi run live-crawl (cadence + cycle variability, for both arms and legs — the crawl overlay leads with the legs and a "favors one leg" readout, since that is where Remy's signal is), or --live-metrics on pose and rerun. motor_metrics/live.py feeds a rolling window to the same hold_metrics/crawl_metrics the offline table uses. Cost was never the obstacle (~3 ms per recompute against a 33 ms frame); the constraints are that the Savitzky-Golay fit leaves the last 3 samples extrapolated — so the readout is deliberately 100 ms old, where it equals the offline value exactly — and that without an annotator there is no honest trial boundary, so the window is fixed and nothing infers movement onset. SPARC, submovement counts and any duration metric are therefore still offline-only: they need an onset/offset the code is not entitled to invent. Live values never enter the .h5 or the offline table (different window, different measurement)
  • child-facing live display — the same readout driving something motivating rather than a numeric overlay. Note "held for N seconds" is not available (that is the loss-of-posture inference motor_metrics refuses); "coverage green and trunk within X of its own baseline" is. First piece landed: pixi run live now draws a sit-hold steadiness meter — a red→green fill bar reading good-vs-bad on a continuum, built on the trunk's deviation from its own rolling baseline (so a tilted camera shifts the baseline, not the score) rather than an absolute upright angle. Still a numeric overlay around it; the game/animation layer is the rest. Second honest signal available: live crawl now reports live_leg_amplitude_symmetry — a continuous "favors one leg" reading (0 = even, sign = side) that survives a tilted camera (it reads no vertical). It is the natural driver for a use-both-legs game — reward closing the gap toward even — the direct counter to Remy favoring one leg. Only the meter is drawn so far; wiring either signal to something motivating is the open work
  • refactor parts of CLAUDE.md into distributed rules, skills, hooks, commands, etc. All context is not needed for every prompt.
  • fuse the Feather Sense IMU into the metrics — blocked on camera↔IMU clock alignment: the recording stores the device clock (ms since board boot) but not its offset to the host timeline. Would give a true gravity vector (no level-camera assumption) and 100 Hz sway
  • program feather sense in C++ with Zephyr RTOS, or embedded Rust (embassy-nrf and nrf-hal)
  • program feather sense in embedded Rust (embassy-nrf and nrf-hal). Use schematics from adafruit to build BSP.