Skip to content

Commit

Permalink
decArgo_20220922_052a commit
Browse files Browse the repository at this point in the history
  • Loading branch information
couppeym committed Nov 24, 2022
1 parent c1bbd5a commit 8f47acd
Show file tree
Hide file tree
Showing 56 changed files with 4,608 additions and 8,381 deletions.
Binary file modified decArgo_doc/decoder_versions/_argo_decoder_versions.xlsx
Binary file not shown.
Original file line number Diff line number Diff line change
Expand Up @@ -57,7 +57,7 @@ CONF_PARAM_DEC_ID;CONF_PARAM_MSG_ID;CONF_PARAM_MSG_LABEL;CONF_PARAM_NAME;CONF_PA
608;251;Maximum value of transmitted CTD temperature measurements (in milli-DegC).;CONFIG_CtdMaxTransmittedTemperature_mdegC;Maximum value of transmitted Ctd temperature measurements (in milli-DegC).
609;251;Minimum value of transmitted CTD salinity measurements (in milli-PSU).;CONFIG_CtdMinTransmittedSalinity_mpsu;Minimum value of transmitted Ctd salinity measurements (in milli-PSU).
610;251;Maximum value of transmitted CTD salinity measurements (in milli-PSU).;CONFIG_CtdMaxTransmittedSalinity_mpsu;Maximum value of transmitted Ctd salinity measurements (in milli-PSU).
613;251;Maximum value of transmitted CTD salinity measurements (in milli-PSU).;CONFIG_CtdIgnoreSamplesWhenPumpActive_LOGICAL;Ignore sample measurements acquired while the hydraulic pump is running (Yes=1/No=0).
613;251;Maximum value of transmitted CTD salinity measurements (in milli-PSU).;CONFIG_AUX_CtdIgnoreSamplesWhenPumpActive_LOGICAL;Ignore sample measurements acquired while the hydraulic pump is running (Yes=1/No=0).
614;251;Maximum value of transmitted CTD salinity measurements (in milli-PSU).;CONFIG_PressureOffsetResetAtSurface_LOGICAL;Reset the surface pressure offset value when the float is at the surface (Yes=1/No=0)
615;-1; = PC 0 1 4 + 0 if 'raw' = PC 0 1 4 + 0.5 otherwise;CONFIG_CTDPumpStopPressurePlusThreshold_dbar;The sum of CONFIG_CTDPumpStopPressure_dbar plus a pressure threshold or overlap (Poverlap). For PROVOR floats, Poverlap is defined as follows: Poverlap = bin_size/2 for PROVOR floats with software versions < 5816A00 and ARVOR floats with software versions < 5605A00. Poverlap = 0.5 dbar for PROVOR floats with software versions >= 5816A00 and ARVOR floats with software versions >=5605A00.
620;251;Minimum value of transmitted OPTODE D phase measurements (in degrees).;CONFIG_OptodeMinTransmittedDPhase_angularDeg;Minimum value of transmitted Optode D phase measurements (in degrees).
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -316,39 +316,39 @@
"CONF_PARAM_DEC_ID" : "500",
"CONF_PARAM_MSG_ID" : "251",
"CONF_PARAM_MSG_LABEL" : "Sampling period of the <Sensor> during the descent to parking pressure in the depth zone #<Z> (in seconds).",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>DepthZone<N>DescentToParkPresSamplingPeriod_seconds",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>DescentToParkPhaseDepthZone<N>SamplingPeriod_seconds",
"CONF_PARAM_DESCRIPTION" : "Sampling period of the <short_sensor_name> during the descent to parking pressure in the depth zone #<N> (in seconds)."
},
"CONF_PARAM_41" :
{
"CONF_PARAM_DEC_ID" : "501",
"CONF_PARAM_MSG_ID" : "251",
"CONF_PARAM_MSG_LABEL" : "Sampling period of the <Sensor> during the drift at parking pressure in the depth zone #<Z> (in minutes).",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>DepthZone<N>DriftAtParkPresSamplingPeriod_minutes",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>ParkDriftPhaseDepthZone<N>SamplingPeriod_seconds",
"CONF_PARAM_DESCRIPTION" : "Sampling period of the <short_sensor_name> during the drift at parking pressure in the depth zone #<N> (in minutes)."
},
"CONF_PARAM_42" :
{
"CONF_PARAM_DEC_ID" : "502",
"CONF_PARAM_MSG_ID" : "251",
"CONF_PARAM_MSG_LABEL" : "Sampling period of the <Sensor> during the descent to profile pressure in the depth zone #<Z> (in seconds).",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>DepthZone<N>DescentToProfilePresSamplingPeriod_seconds",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>DescentToProfPhaseDepthZone<N>SamplingPeriod_seconds",
"CONF_PARAM_DESCRIPTION" : "Sampling period of the <short_sensor_name> during the descent to profile pressure in the depth zone #<N> (in seconds)."
},
"CONF_PARAM_43" :
{
"CONF_PARAM_DEC_ID" : "503",
"CONF_PARAM_MSG_ID" : "251",
"CONF_PARAM_MSG_LABEL" : "Sampling period of the <Sensor> during the drift at profile pressure in the depth zone #<Z> (in minutes).",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>DepthZone<N>DriftAtProfilePresSamplingPeriod_minutes",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>ProfDriftPhaseDepthZone<N>SamplingPeriod_seconds",
"CONF_PARAM_DESCRIPTION" : "Sampling period of the <short_sensor_name> during the drift at profile pressure in the depth zone #<N> (in minutes)."
},
"CONF_PARAM_44" :
{
"CONF_PARAM_DEC_ID" : "504",
"CONF_PARAM_MSG_ID" : "251",
"CONF_PARAM_MSG_LABEL" : "Sampling period of the <Sensor> during the ascending profile in the depth zone #<Z> (in seconds).",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>DepthZone<N>AscentSamplingPeriod_seconds",
"CONF_PARAM_NAME" : "CONFIG_<short_sensor_name>AscentPhaseDepthZone<N>SamplingPeriod_seconds",
"CONF_PARAM_DESCRIPTION" : "Sampling period of the <short_sensor_name> during the ascending profile in the depth zone #<N> (in seconds)."
},
"CONF_PARAM_45" :
Expand Down Expand Up @@ -468,7 +468,7 @@
"CONF_PARAM_DEC_ID" : "613",
"CONF_PARAM_MSG_ID" : "251",
"CONF_PARAM_MSG_LABEL" : "Maximum value of transmitted CTD salinity measurements (in milli-PSU).",
"CONF_PARAM_NAME" : "CONFIG_CtdIgnoreSamplesWhenPumpActive_LOGICAL",
"CONF_PARAM_NAME" : "CONFIG_AUX_CtdIgnoreSamplesWhenPumpActive_LOGICAL",
"CONF_PARAM_DESCRIPTION" : "Ignore sample measurements acquired while the hydraulic pump is running (Yes=1/No=0). "
},
"CONF_PARAM_60" :
Expand Down
Loading

0 comments on commit 8f47acd