Notifications
You must be signed in to change notification settings - Fork 5
REMKO Command table (version 4.23)
Joël van Amerongen edited this page Jun 18, 2023
·
4 revisions
The below codes are used the get and set parameters for your device.
REMKO Code | Parameter | Description |
---|---|---|
1079 | 00 | Domestic Hot Water - Auto Comfort |
1079 | 01 | Domestic Hot Water - Auto eco |
1079 | 02 | Domestic Hot Water - Solar / pv |
1079 | 03 | Domestic Hot Water - Off |
1082 | 01CC | DHW requested water temp |
1088 | 01 | Heating / Cooling - Automatic |
1088 | 02 | Heating / Cooling - Heating |
1088 | 03 | Heating / Cooling - Standby |
1088 | 04 | Heating / Cooling - Cooling |
2263 | 00BE | Cooling Fixed value - 19 °C |
2263 | 00C8 | Cooling Fixed value - 20 °C |
Temperatures are parsed in 4 digits hexadecimal values and the temperature is always x10. So 45 degrees Celsius is 450, Converted to 4 digits hex = "01C2".
This tool can help to convert values: https://www.rapidtables.com/convert/number/decimal-to-hex.html